Frame Relay: DLCI LMI status, what does this mean? [acheiving] [responsibilty]

admin / January 19th, 2011/ Posted in Networking / No Comments »

Q: What does the state tell me about a DLCI frame relay PVC, and where the responsibility for achieving this status is?

For example, in a simple point-to-point scenario, if a DLCI is advertised as “Inactive”, which of the four components is most likely the problem: local router, local switch, router, remote, remote switch be?

Is there a logical way for the possible reasons for DLCI status, either active, inactive or removed to provide?


Music Career Masters
Re:I just finished that part of the CCNA (Mod 4)..

I found that they always seem to put the blame on the Remote connection.. works for me, and it's right, according to Cisco..

:D


Web Design Business Startup Kit
Re:that's correct. If the other router hasn't brough up the PVC (via LMI) then the pvc is inactive.

The PVC is marked active when both ends have it up.

Even though the communication is with the local frame switch, and that is where the status is sent from – the PVC has to be up from end to end to be active.


Life Changing Self Hypnosis MP3s By Email.
Re:I'm still a bit confused.

Cisco.Com has a new CCNA Prep Center that has 4 free practice exams. One of the exams has a question :

Frame Relay is configured over a point-to-point connection between two routers. The output of the show frame-relay pvc command indicates the status of this PVC is inactive. Which of the following devices could be the source of the problem ? (Choose two.)

1. Local Router
2. Local Frame Relay Switch
3. Remote Router
4. Remote Frame Relay Switch

Cisco sais the answer is Remote Router and Remote Frame Relay Switch.


The Ultimate Guide To Parrots – Step by Step
Re:Acitve – DLCI is defined on router and in LMI full status updates as active
Inactive – DLCI is defined on router and declared inactive by frame switch
Deleted – DLCI is not defined on router or not in LMI updates

all of this information is being relayed via LMI full status updates. These are being sent by the frame switch, regardless of far end.

-edit- could go into more detail, but its all about what the frame switch says. Remember, you're talking to the frame switch, not the other router.


Just Launched! Brand New High Conversion Make Money System.
Re:Active – Both ends agree and are up

Inactive – Both ends agree, Near end is up, far end is down

Deleted – The endpoints disagree on the DLCI assignment (or DLCI not assigned on the near end), near end is up (but without dlci assignment), far end is up (but sees no valid DLCI from the near end)

FWIW

Scott


Dry Cell Plans
Re:Doesn't look like there's a definitive solution here, but some suggestions; http://www.practical-tech.com/network/n061402.htm
Here they recommend calling your frame relay provider: http://www.cisco.com/warp/publ…_notes/kb/C000259.html (http://www.cisco.com/warp/public/707/cscsupport/tech_notes/kb/C000259.html)

Related posts


Tags: ,

Leave a Reply

Name required

Mail (will not be published) required

Website